Advertorial

TERS solution shows immediate results after installation

0
SHARES

Posted: 4 January 2016 | | No comments yet

Joint HORIBA and AIST-NT solution provided spatial resolution below 15 nm…

Horiba - TERS Solution Shows Immediate Results After Installation

Figure: GO, SWCNTs and fullerenes C60 co-deposited on gold. (a) Combined TERS map 4x4 μm, 128 pixels per line, 100ms per pixel. Individual maps showing the distribution of components, (b) graphene oxide, (c) fullerenes C60, (d) CNTs. All carbon species can be detected and resolved.

HORIBA Scientific, global leader in Raman spectroscopy solutions, and AIST-NT, manufacturer of advanced SPM systems designed specifically for integration with optical spectroscopy, deployed their joint solution at Oak Ridge National Laboratory, in the US, in collaboration with the Technische Universität Chemnitz, Germany.

 

Reserve your FREE place

 


Address the time-to-result challenge posed by short shelf-life radiopharmaceuticals.

20 November 2025 | 3:00 PM GMT | FREE Virtual Panel Discussion

This webinar showcases the Growth Direct System; an RMM (Rapid Microbial Method) that improves on traditional membrane filtration, delivering increased accuracy, a faster time to result, enhanced data integrity compliance, and more control over the manufacturing process.

Key learning points:

  • Understand the benefits of full workflow microbiology quality control testing automation in radiopharmaceutical production
  • Learn about ITM’s implementation journey and considerations when evaluating the technology
  • Find out how the advanced optics and microcolony detection capabilities of Growth Direct® technology impact time to result (TTR).

Don’t miss your chance to learn from experts in the industry – Register for FREE

 

Horiba - TERS Solution Shows Immediate Results After Installation

Figure: GO, SWCNTs and fullerenes C60 co-deposited on gold. (a) Combined TERS map 4×4 μm, 128 pixels per line, 100ms per pixel. Individual maps showing the distribution of components, (b) graphene oxide, (c) fullerenes C60, (d) CNTs. All carbon species can be detected and resolved.

The resulting Tip Enhanced Raman Scattering (TERS) data was recently published in an article entitled, ““Nanoscale imaging and identification of a four-component carbon sample” E. Sheremet, R. D. Rodriguez, A. L. Agapov, A. P. Sokolov, M. Hietschold, D. R.T. Zahn, Carbon 96 588-593 (2016).

The data presented in this publication were recorded during the installation of the equipment in Professor Sokolov’s group at Oak Ridge. The authors demonstrate the TERS chemical imaging of the individual components in a four-carbon-allotropes sample: single-wall carbon nanotubes (CNTs), graphene oxide (GO), C60 fullerenes, and an organic residue by the by the presence of corresponding characteristic Raman peaks.

TERS with spatial resolution below 15 nm allowed the analysis of:

  • Localized changes of defect concentration in graphene and graphene oxide
  • Organic residue adsorption on graphene and graphene oxide
  • Doping and defect in carbon nanotubes and their diameter estimation.

HORIBA Scientific and AIST-NT are proud to have these authors as customers and colleagues and we are especially grateful to Dr. Rodriguez, of Professor Zahn’s group, for shepherding this work through the publishing process. More information can be found at: www.horiba.com/raman-afm